Comparative static FEA of equipment foundations on marine vessels: standard, stiffened, and structural integrated

  • Oana Mirela Jarcă “Dunarea de Jos” University of Galati
  • Dumitru Silviu Perijoc “Dunarea de Jos” University of Galati
Keywords: equipment foundations, ship integrated foundation, static FE analysis.

Abstract

This study case presents a comprehensive static finite element analysis (FEA) of an equipment foundation aboard a marine vessel, conducted in three distinctive scenarios. The initial analysis adheres to a generalized standard, providing a baseline for structural performance. Subsequently, the same foundation is re-evaluated with the addition of stiffening brackets, aimed at enhancing rigidity and load distribution capabilities. The final
analysis transitions from the theoretical models to practical application, examining the foundation as it is truly mounted and integrated within the ship's structure. Each scenario is meticulously compared to assess the impact of design modifications and integration on the foundation's performance.

References

[1]. Domnişoru L., “Analiza structurilor navale prin metoda elementului finit . Aplicatii numerice”, Editura Fundaţiei Universitare “Dunărea de Jos”, Galaţi, 2009
[2]. DNVGL, 2021, “Modeling and Analysis of Marine Operations”, Recommended Practice, DNV-RP-H103, https://rules.dnvgl.com.
[3]. Germanischer Lloyd, 2023, “Rules and Guidelines, Part I Sea Going Ships”
[4]. FEMAP 2023. “NX NASTRAN 5.0 User’s Guide”
Published
2023-12-04
How to Cite
1.
Jarcă O, Perijoc D. Comparative static FEA of equipment foundations on marine vessels: standard, stiffened, and structural integrated. Annals of ”Dunarea de Jos” University of Galati. Fascicle XI Shipbuilding [Internet]. 4Dec.2023 [cited 28Apr.2024];46:125-32. Available from: https://www.gup.ugal.ro/ugaljournals/index.php/fanship/article/view/6304