FLAMMABILITY TESTS ON HOT SURFACE FOR CASTOR OIL
Abstract
For this paper, the authors studied the behavior of castor oil, when it accidentally reaches a hot surface. Thus, the lowest temperature at which castor oil ignited at least once in three tests and the highest temperature at which castor oil did not ignite in three tests were determined. To determine as accurately as possible these two temperatures, a total of 29 tests were performed. The procedure complies with ISO 20823:2018 Petroleum and related products -Determination of the flammability characteristics of fluids in contact with hot surfaces - Manifold ignition test.
All rights are reserved for this publication, which is copyright according to the Romanian law of copyright. Excepting only any fair dealing for the purpose of the private study, research, review, comment and criticism, no part of this publication may be reproduced, stored in a retrieval system or transmitted in any form or by any means, mechanical, electrical, electronic, optical, photocopying, recording or otherwise, without the prior express permission of the copyright owners.